Projects

  1. Home
  2. hot products
  3. dust collector static electricity

Dust Collector Static Electricity

Whatever your requirements, you 'll find the perfect service-oriented solution to match your specific needs with our help.We are here for your questions anytime 24/7, welcome your consultation.

Chat Online
  • Static Electricity How To Fight It

    Static Electricity How To Fight It

    Dec 15 2014 you might also check the continuity of the ground on everything machine spindle bob power supply computer fuse or breaker panel electrical outlets light switches extension cords and cords of the dust collector or shop vac if static electricity has not been a problem in the past but is now a problem something in the wiring on the machine spindle dust collector or shop vac bob power

    Live Chat
  • Dust Collection And Static Electricity By

    Dust Collection And Static Electricity By

    May 18 2015 recently i purchased a 34 hp jet dust collector for a steal off of cl and considering its size it fits into my corner of the garage a lot better than some of the others i have seen or could afford as i was finishing up the dust collector connection for my table saw last night i started thinking about this whole static electricity thing

    Live Chat
  • Exploding Pvc Dust Collection Ductwork

    Exploding Pvc Dust Collection Ductwork

    Answer from rob johnstone "let me start out by saying that in over 25 years of woodworking i have never heard of an actual explosion or fire resulting from the static electricity on the plastic dust collection tubes danger tons of ink both real and virtual have been spilled discussing and debating this issue

    Live Chat
  • Building Adust Collection Systemwith Pvc Piping

    Building Adust Collection Systemwith Pvc Piping

    Jan 26 2017 in a dust collection piping system one must always consider the dangers of static electricity this is especially true when plastic piping such as pvc is being used if static electricity is charged it can be discharged in the form of dangerous sparks that will shock a user or even ignite the flammable sawdust inside the pipes

    Live Chat
  • Safety  Is Pvc Pipe Safe To Use For Adust Collection

    Safety Is Pvc Pipe Safe To Use For Adust Collection

    Pvc is commonly used in dust collection systems typically for longer runs you should use 6" or larger pipe regardless of the material if youre using pvc the larger less expensive pipe is commonly available as sewer drain pipe as of may 2015 there have been no known fires caused by a static discharge in a pvc pipe from a dust collection system

    Live Chat
  • Dust Collection And Pvc Static Fire Danger  The Newbie

    Dust Collection And Pvc Static Fire Danger The Newbie

    Jan 21 2020 one of the most common topics i see in the comments on my dust collection for newbies video is about the perceived dangers of static electricity and pvc and whether you need to ground your system or not ive finally decided to put my thoughts on the subject in a blog post so i dont have to repeat myself every time

    Live Chat
  • Static Electricity And Dust Problem Swedish Electrostatics

    Static Electricity And Dust Problem Swedish Electrostatics

    Here is a continuation of the subject static electricity where we focus on studying the problems of unwanted particles and health problems associated with static electricity it may sound a little strange that static electricity could have an impact on dust and health problems or if you like problems with unwanted particles

    Live Chat
  • The Basics Of Dust Extraction Knowledge Articles  Carbatec

    The Basics Of Dust Extraction Knowledge Articles Carbatec

    One hazard that is often overlooked in dust extraction equipment is the danger of the buildup of static electricity the dry timber particles rubbing the inside of the flexible hose are constantly building a static charge in the same way rubbing a plastic comb through your hair if you have any will build up a static

    Live Chat
  • How To Makea Diy Dust Collector For Your Shop Sawshub

    How To Makea Diy Dust Collector For Your Shop Sawshub

    A dust collector is a tool that collects the wood byproducts produced by power tools whether these are wood chips wood shavings or dust it keeps the area where youre working clean first ground the container to reduce the chances of sparks caused by static electricity run the bare copper wire through the containers interior to

    Live Chat
  • Grounding Your Dust Collection System By Will Stokes

    Grounding Your Dust Collection System By Will Stokes

    Feb 01 2010 homeshop dustcollection systems have become increasingly popular but their safety has been hotly debated the primary issue is whether pvc pipe is safe for use as ductwork many claim that sparks in pvc pipe due to static electricity may ignite the dust cloud in the pipe the specter of a giant fireball consuming a shop and home is

    Live Chat
  • What Areantistatichoses Staticdissipative

    What Areantistatichoses Staticdissipative

    Jun 09 2020 antistatic dust collection hoses often referred to an antistatic hose the design of a static dissipative hose is to mitigate or prevent static electricity by dissipating it through the rubber material to the hose ends here are some of our static dissipative hoses

    Live Chat
  • Grounding Dust Collection Hosewoodweb

    Grounding Dust Collection Hosewoodweb

    If you look elsewhere in the archives there is a site to a study that indicates that there is nothing to worry about in small diameter tubes the static discharges if any are insufficient to ignite even the worst dustair mixes the wire is of no value the reason that the static builds up in the first place is that the plastic is an insulator

    Live Chat
  • Grounding Cncdust Collectorvectriccustomer

    Grounding Cncdust Collectorvectriccustomer

    Mar 05 2014 i read somewhere that the static discharges on a dust collector hose can be of such a small voltage they are not sensed by us as "shocking" but they are large enough to affect sensitive electronics of a cnc controller angie ps i used hot glue to reseal the holes in the dust collector hose

    Live Chat
  • How To Ground A Pvc Pipe  Ehow

    How To Ground A Pvc Pipe Ehow

    Using pvc pipe as a dust collection system in a home shop is generally considered to constitute a low risk of static buildup leading to explosion however using pvc pipe for industrial or largescale applications is not widely approved and in such cases metal should be considered the best choice for ventilation electricity is extremely

    Live Chat
  • Grounding For Dust Collectionfinewoodworking

    Grounding For Dust Collectionfinewoodworking

    Jul 01 2013 the first time i used it i noticed a 1 long spark arcing between the dust collection hose and the planer table promptly turned it off and installed a grounding wire in the new shop the main dust collection trunk line is 5 26 gauge galvanized duct but the

    Live Chat
  • Static Electricity Vectric Customer

    Static Electricity Vectric Customer

    Oct 23 2018 from what ive seen dust collector static will cause a limit switch mechanical to trip at first when i experienced that problem i upped the bounce setting and the problem went away i then added a ground wire in the collector hose because i was getting tired of getting shocked

    Live Chat
  • Controllingstaticin Mydustvacuum Hoses  Inventables

    Controllingstaticin Mydustvacuum Hoses Inventables

    Oct 06 2015 anyone who has used flexible plastic hoses to connect shop tools has felt the effect of the static buildup unless the hose has a reinforcing wire that can be grounded to the dust collector in the case of pvc rigid pipe similar static charge buildup will occur and some prudent folks add a bare drain wire to remove the charge

    Live Chat
  • Groundingdust Collectortube  The International

    Groundingdust Collectortube The International

    Jan 02 2021 now with that said it would take a long time for this static to build in a 4" to 6" dust collector system and you have more than fine dust running through it aka chips of wood but many people like to be on the safe side because a home or shop is a place where there is constant dust problems again 2 theorys on how to ground a pvc pipe system

    Live Chat
  • Dust Collectorhoods  Mcmastercarr

    Dust Collectorhoods Mcmastercarr

    Designyourown dust collector duct system use these components sold separately to put together a duct system to collect sawdust chips shavings and granular material from woodworking operations hose clamps are available for maximum safety and to avoid a dangerous buildup of static electricity you must use the grounding kit sold

    Live Chat
  • Staticelectricty And The Sawdust Collectionsystem

    Staticelectricty And The Sawdust Collectionsystem

    May 22 2018 from a retired electrician it sounds to me like you did a perfect job of bonding to eliminate the static electricity build up at present im using a shop vac with a couple of long hoses but plan to install 3" pvc in the near future and will follow your plan im thinking of using pvc conduit 90 degree elbows as they have a lot longer radius

    Live Chat
  • Staticresistance  The Industry Leader Indust Collection

    Staticresistance The Industry Leader Indust Collection

    Any dust collection environment can be prone to static charge buildup because of this oneida air uses metal antistatic static dissipative and static conductive materials in our products refer to the table below for more info

    Live Chat
  • Dust Collection Static Build Uppractical Machinist

    Dust Collection Static Build Uppractical Machinist

    Jan 11 2013 i made a dust collection system for my shop out of pvc 20 years ago and its worked just fine since the day it was installed to avoid static electricity discharge i ran electric fence wire the internally the entire length the fence wire is grounded to the water pipe we still have copper tube and a copper ground stake outside

    Live Chat
  • Shop Vacs And Static Electricity Finewoodworking

    Shop Vacs And Static Electricity Finewoodworking

    Sep 17 2005 there was a thread her sometime back in which someone posted a study done on dust collection systems from an mit professor who himself is a hobbyist woodworker he said there has never been a documented incident of a fire started by static electricity in a dust collection system which would include a shop vac

    Live Chat
  • Dust Collectorductwork Mcmastercarr

    Dust Collectorductwork Mcmastercarr

    For maximum safety and to avoid a dangerous buildup of static electricity you must use the grounding kit sold separately if you need more information on designing and installing a dust collection system order our book "dust collection basics"

    Live Chat
  • Dust Collection Frequently Asked Questions Air Handling

    Dust Collection Frequently Asked Questions Air Handling

    Static pressure is pressure which is exerted against the walls of an air duct that is created by friction and impact of air as it moves the average static pressure of most small dust collection systems is 8 to 10 in other words a furnace blower does not have enough strength to overcome the static pressure of a central dust collection

    Live Chat

WHY CHOOSE US?

With excellent product quality and good after-sales service, it has been highly praised in domestic and overseas markets and won the favor of many querys around the world.

More info

Contact Us

Address: High-tech Zone, Zhengzhou, China

Email: [email protected]

More info

Copyright © 2015.TENIC Heavy Machinery Co., Ltd., All rights reserved. Sitemap